Page:NIOSH Manual of Analytical Methods - 1024.pdf/2
This page has been proofread, but needs to be validated.
1,3-BUTADIENE: METHOD 1024, Issue 2, dated 15 August 1994 - Page 2 of 8
REAGENTS:
- Methylene chloride,[1] chromatographic quality with hydrocarbon (cyclohexene) preservative.
- 1,3-Butadiene,[1] 99.5%, in cylinder equipped for gas withdrawal, with needle valve.
- Helium, purified.
- Hydrogen, purified.
- Air, purified.
- Nitrogen, purified.
- Water, distilled.
EQUIPMENT:
- Sampler: Tandem charcoal tubes. Each tube is flame-sealed glass (8.5 cm long, 8-mm OD, 6-mm ID), has plastic caps for resealing, and contains activated coconut shell charcoal (such as SKC Lot 120) preceded by silylated glass wool and followed by a 3-mm urethane foam plug. The front tube holds 400 mg charcoal. The back tube holds 200 mg.
- Personal sampling pump, 0.01 to 0.5 L/min, with flexible connecting tubing./li>
- Refrigerant, bagged (e.g., Blue Ice or dry ice), and insulated shipping container.
- Gas chromatograph, flame ionization detector, integrator, and column (see APPENDIX A).
- Ice, wet.
- Vials, 5-mL, 2-mL, 1-mL, and other convenient sizes, with PTFE-lined septum caps.
- Pipettes, TD, 4-, 2-, and 1-mL.
- Syringes, gas-tight, 250-, 100-, 25-, and 10-µL.
- Beaker, 150-mL.
- Gas drying tube with serum cap to fit stem and 2-cm piece of plastic tubing to fit over serum cap.
SPECIAL PRECAUTIONS: 1,3-Butadiene is a potential carcinogen, teratogen, and reproductive hazard [2]. Methylene chloride is toxic, very volatile, and a suspect carcinogen [3]. Work should be performed in a well-ventilated fume hood.
SAMPLING:
- Calibrate each personal sampling pump with a representative sampler in line.
- Immediately before sampling, break ends of sampler tubes. Connect smaller tube to personal sampling pump with flexible tubing and to larger tube with a short piece of plastic tubing.
- Sample at an accurately known flow rate of 0.01 to 0.5 L/min for a sample size of 5 to 25 L.
- Separate the tubes, cap, and pack securely for shipment. Chill below –4 °C during shipment and storage.
SAMPLE PREPARATION:
- Add 4.0 mL methylene chloride to 5-mL vials and 2.0 mL to 2-mL vials. Loosely cap vials and thoroughly chill in ice.
- Place front sorbent sections in 5-mL vials and back sections in 2-mL vials. Discard glass wool and foam plugs. Immediately cap each vial.
- Remove from ice and allow to stand 30 min with occasional agitation.
- Transfer sample solution to appropriate vial and cap if using an autosampler. Thoroughly chill solution and vial before making transfer.
NIOSH Manual of Analytical Methods (NMAM), Fourth Edition