Page:NIOSH Manual of Analytical Methods - 5006.pdf/1
CARBARYL
C10 H7OC(=O)NHCH3
MW: 201.22
METHOD: 5006, Issue 2
5006
CAS: 63-25-2
RTECS: FC5950000
EVALUATION: FULL
OSHA : 5 mg/m 3 NIOSH: 5 mg/m 3; Group II Pesticide ACGIH: 5 mg/m 3
PROPERTIES:
Issue 1: 15 May 1985 Issue 2: 15 August 1994
solid; crystal; d 1.230 g/mL @ 20 °C; BP decomposes; MP 142 °C; VP <0.005 Pa (<4 x 10-5 mm Hg; <0.4 mg/m 3) @ 20 °C
SYNONYMS: Sevin; 1-naphthalenol N-methylcarbamate; 1-Naphthyl-N-methylcarbamate
SAMPLING
MEASUREMENT
SAMPLER:
FILTER (glass fiber)
TECHNIQUE:
VISIBLE ABSORPTION SPECTROPHOTOMETRY
FLOW RATE:
1 to 3 L/min
ANALYTE:
p-nitrobenzenediazonium tetrafluoroborate complex
VOL-MIN: -MAX:
20 L @ 5 mg/m 3 400 L
SAMPLE WORKUP:
SHIPMENT:
ship filters in 25-mL scintillation vials
20 mL 0.1 M methanolic potassium hydroxide; to 2-mL aliquot, add 17 mL glacial acetic acid; add 1 mL p-nitrobenzenediazonium tetrafluorobate
WAVELENGTH:
475 nm
CALIBRATION:
Carbaryl in methylene chloride
RANGE:
0.1 to 1.0 mg per sample [2]
ESTIMATED LOD:
0.03 mg per sample [3,4]
PRECISION (Sr):
0.015 [1]
SAMPLE STABILITY: BLANKS:
at least 7 days @ 25 °C [1] 2 to 10 field blanks per set
ACCURACY RANGE STUDIED:
2 to 13 mg/m 3 [1] (90-L samples)
BIAS:
- 0.73%
ˆ rT): 0.057 [1] OVERALL PRECISION (S ACCURACY:
± 11.3%
APPLICABILITY: The working range is 0.5 to 20 mg/m 3 for a 200-L air sample.
INTERFERENCES: Phenols such as 1-naphthol will give a positive interference [2]. Interferences from other aromatic carbamates and phenoxyacetic acid pesticides may occur but have not been documented.
OTHER METHODS: This revises Method S273 [2].
NIOSH Manual of Analytical Methods (NMAM), Fourth Edition, 8/15/94